I built a people’s repeater and i’m working on setting up a place to mount it. It’ll be atop a steel pole around 20’ (6m) in the air. I am a bit worried about lightning. It won’t be the tallest thing around but i’d assume steel is more conductive than the tree next to it, so i’d like to set up a lightning rod.

The only issue is i don’t know what i’m doing. I got a grounding rod, grounding clamp, and bare copper wire, on the recommendation of someone at the hardware store, but i don’t really understand what to do with them that’ll actually stop my repeater from being struck in a storm.

So how does this work? Is lightning even something to worry about at all?

  • givesomefucks@lemmy.world
    link
    fedilink
    English
    arrow-up
    3
    ·
    18 days ago

    Lightning takes the path of least resistance. The two main points here are height and conductivity.

    There’s math out there that would determine if a 20’ steel pole is more likey to be hit than a X’ tree, and you could even control for the species of tree and time of year, because moisture content is a huge factor for conductivity…

    But I mean, how often is lightning striking there?

    A 20’ steel pole isn’t going to summon Thor from the mountain tops, in all likelihood you’re fine.

    As far as how to ground something…

    It’s really just giving electricity an easy path to the ground, because again, electricity just takes the easiest path. So a taller steel rod will have less resistance than your antenna, because going thru steel is easier than going thru air.

    The clamp holds one end of wire, the other end gets buried. That way the energy dissipates into the ground instead of staying in the steel and turning into heat.

  • litchralee@sh.itjust.works
    link
    fedilink
    English
    arrow-up
    3
    ·
    edit-2
    18 days ago

    Grossly oversimplifying, lightning protection is about managing a strike and its consequences, rather than avoiding the occurrence of one from ever happening (which is impossible to avoid when erecting a tall, metal post). Looking to ham radio operators (that have antennas sometimes over 120 ft (36 m) tall) and cellular phone towers, they are all liable to being struck, but divert the energy to spare the radios and electronics.

    To do that, the exteriors of these structures are all firmly grounded, using a mesh of copper laid along and deep into the ground, extending out to a good fraction of the height of the structure. The antennas are then bonded to this grounding network so that when – not if – a direct strike occurs, that massive current will conduct in an ideally straight line to the earth, to then spread out the current. All conductors involved must be thick enough so that they don’t instantly vaporize from the current. No sharp turns are allowed, because lighting doesn’t honor those suggestions. A direct strike that doesn’t damage the electronics might still be so violent to cause the metal structure to minorly catch fire. But that’s a win when nature could have pulverized the structure instead.

    In the case of an indirect strike (such as lightning striking a tree that is 10 meters away), this grounding still protects the electronics from the massive induced magnetic field, which causes current to flow in any nearby conductor. Shielding of equipment, such as being inside a Faraday caged Telco room, or electronics kept in a sealed, solid, metal (ferrous?) case, will divert this magnetic field.

    But that’s the theory for big installations. You have a MeshCore antenna atop a pole. What you should be doing is grounding the pole as best as you can (ie one or two ground rods driven into the soil), bonding the pole to the ground wires of nearby structures (ie to your house’s water pipe), and then shielding your radio in a sturdy metal container (ie something more substantial than an Altoids tin).

    The mistake people make is to think that all this will avoid a lightning strike ever. No, your pole will be hit but you can still save the radio, save your house from catching fire, and stand a decent chance of also saving the antenna. Even if you don’t put a MeshCore radio at the top, a 6 meter metal post ought to be grounded (connecting to the foundation rebar is usually enough) and if nearby the house, bonded to its ground network.

  • Onomatopoeia@lemmy.cafe
    link
    fedilink
    English
    arrow-up
    1
    ·
    18 days ago

    Wouldn’t you want an actual lightning rod that extends above the pole/repeater?